Whole-House Generator Sizing: Which Circuits to Protect and How to Manage the Load
This is a GUIDE, not a calculator and not a recommendation. It shows you how to build your own load list, which circuits to protect, and how to manage simultaneous use. There is no one “whole-house size” — Generac’s own guidance sizes by load, not square footage (a ~1,550 sq ft home: 10–18 kW; a ~2,000 sq ft home: 18–22 kW — context only). Your panel’s loads decide; a dealer site survey that measures your actual panel loads is the most reliable way to get a final number (Generac). No page on this site will auto-recommend a size from your inputs. For a shorter outage, the same essentials can run from a 3,000Wh portable power station instead.
⚠️ Generator safety — read first.
Never plug a generator into a wall outlet and never backfeed your house wiring — it can kill line workers and destroy the generator when power returns. To power house circuits, use a transfer switch or inlet box installed by a qualified professional.
Run a portable generator outdoors only, at least 20 feet (6 m) from doors, windows and vents, with the exhaust pointed away from the house (CDC). Never run it in a home, garage, basement or shed — a garage with the door open is NOT safe. Fit battery-operated carbon monoxide alarms in your home, near sleeping areas. Let the engine cool before refuelling, and store fuel outside living areas in labelled containers.
Scope: North America only — 120/240V split-phase, 60 Hz residential and RV systems. This guide does not cover other countries’ voltages or frequencies, or industrial three-phase power.
Connecting a generator to house wiring is a job for a qualified professional, with a permit where your jurisdiction requires one. A transfer switch, interlock kit or inlet box must be listed for your panel and installed per its listing — your local inspector (the authority having jurisdiction) has the final word. Never connect a generator to a plain breaker.
Answer Table 1 — The three coverage strategies
Generac’s classes: essentials / comforts / heavy hitters. Size to loads, not square footage.
| Strategy | What it covers | Hardware | Typical size |
|---|---|---|---|
| Essential circuits only | Fridge, freezer, furnace fan, sump pump, lights, internet, a few outlets (W1 below) | Portable generator + manual transfer switch (6–10 pre-selected circuits) or interlock kit + inlet box | 5000–7500W portable, or 7–13 kW standby |
| Managed whole house | Essentials + comforts + one heavy hitter at a time, with load shedding (W2 below) | Larger portable (12000W class) or 14–18 kW standby with load management / soft start | 12000W portable, or 14–18 kW standby |
| Complete whole house | Everything, including central AC + dryer + water heater together (W3 below) | Large standby with load management; no portable covers it | 18–22 kW standby for a ~2,000 sq ft home (Generac band); W3 as listed exceeds even that on the running check — shed loads first |
Answer Table 2 — Worked load lists
All values from the wattage table (Honda / Champion / Generac). R = running total; D = largest single surge delta (counted once — motors start one at a time); P = R + D; Need = R × 1.2. Surge allowance = running rating × 1.25 as a planning assumption — check your unit’s actual surge rating.
| # | Load list | R (W) | D (W) / motor | P (W) | Need R×1.2 (W) | What covers it |
|---|---|---|---|---|---|---|
| W1 | Critical circuits: fridge 192 + freezer 500 + furnace fan 700 + sump pump 1,050 + LED lights 150 + TV 190 + laptop/phones 300 + router 20 + CPAP (heated) 120 | 3,222 | 1,100 / sump | 4,322 | 3,866 | 5000W-class portable (surge allowance 6,250 ≥ 4,322) or a 7500W-class portable with margin. This is the list a 6–10 circuit manual transfer switch is built for. |
| W2 | Larger list: W1 + well pump 1 HP 2,000 + microwave 1,500 + dishwasher 2,400 | 9,122 | 2,000 / well | 11,122 | 10,946 | 12000W-class portable (surge 15,000 ≥ 11,122) or a 14 kW standby. A 10000W-class portable FAILS the running check (10,946 > 10,000 by 946W). |
| W3 | Whole-house attempt: W2 + electric dryer 6,000 + electric water heater 4,500 + 3-ton central AC 3,500 (Champion planning figure) | 23,122 | 2,500 / AC | 25,622 | 27,746 | No portable, and no standard air-cooled standby as listed. Under Generac’s AC starting figure (18,000W): P = 23,122 + 14,500 = 37,622. Shed list (in this order): dryer → water heater → central AC (or AC with soft start + load manager) → dishwasher. Shedding dryer + water heater + AC leaves W2 (9,122W / 11,122W peak) — a 12000W-class portable or 14 kW standby. |
Answer Table 3 — Transfer switch vs interlock kit vs inlet box
All three need an outdoor inlet box, a permit/inspection in most jurisdictions, and a qualified professional (electrician). Prices are 2026 cost-guide ranges, not quotes — verify current pricing.
| Manual transfer switch | Interlock kit | Power inlet box | Automatic transfer switch (ATS) | |
|---|---|---|---|---|
| What it is | A small sub-panel beside the main panel; the electrician moves 6–10 (up to 16) circuits you choose into it; one LINE / OFF / GEN switch per circuit; many models have wattmeters | A sliding metal plate on the main panel cover; the main breaker and a new generator breaker (typically 30A or 50A) can never both be ON | The weatherproof socket on the outside wall where the generator cord plugs in | Senses the outage, starts the standby generator and moves the load with no one home |
| Circuits you can run | Only the pre-selected 6–10 | Any circuit in the panel, one budget at a time | None by itself — it is not a safety device on its own | Whole panel (standby units) |
| Load management | Limited by design (only mapped circuits can draw) | By hand — you flip breakers off yourself | — (must be wired to a transfer switch or an interlocked breaker, never to a plain breaker) | Automatic load management / shedding |
| Who installs | Qualified professional | Qualified professional; kit must be listed for your exact panel | Qualified professional | Qualified professional (standby installs) |
| Typical installed cost (2026 guides) | ~$400–$1,300 | ~$400–$850 | Included in the ranges above | Part of a standby install |
| Pick it when | Other people in the house will run things during an outage; your panel has no listed interlock kit; your inspector prefers it | Your panel has a listed kit, you want the whole panel reachable, and you will manage the load by hand | Always — with one of the options left of it | You have a standby generator |
Code note — reference only
NEC Article 702 (optional standby systems) requires listed transfer equipment installed so the normal supply and the standby supply can never be connected to each other. An interlock kit counts when it is listed for your exact panel and installed per that listing. Your local inspector (the authority having jurisdiction) has the final word. No code text is reproduced on this page.
How to build your load list — 5 steps
- Walk the panel: Open the breaker panel and write down every circuit: what it feeds, its breaker amps, and whether it is 120V or 240V. Photograph the panel schedule; fill in any blanks by switching breakers off one at a time and seeing what stops.
- Sort every circuit into Generac’s three classes: Essentials: fridge, freezer, furnace fan, sump pump, lights, router, medical devices (CPAP). Comforts: microwave, dishwasher, garage door opener, window AC, TV, laptop chargers. Heavy hitters: central AC, electric range, well pump, electric dryer, electric water heater, EV charger.
- Write running watts AND starting watts for every motor load: Nameplate, manual, or the wattage table as a planning figure. Resistive loads (dryer, water heater, range, dishwasher) need running watts only. If a motor’s starting watts are unknown, that circuit’s verdict is CANNOT CONFIRM until you find them.
- Build three lists, not one: The critical list (W1 — what must stay on), the larger list (W2 — what you want on), and the whole-house list (W3 — everything). Run the sizing method on each: R, largest single D, P, need R × 1.2. The list that fits your generator is your outage plan.
- Decide the hardware with an electrician: Transfer switch (6–10 circuits, foolproof) or interlock kit (whole panel, you manage the load) — see Table 3 — plus the inlet box and cord sized to the generator’s outlet (30A L14-30 = 7,200W max; 50A 14-50 = 12,000W max). Get the permit where required. Test the whole setup before the first real outage.
Bill of Materials (BOM) — Whole-House Generator Kit
Installed by a qualified professional unless noted; verify ratings on the spec sheet, not the box number:
- Manual transfer switch kit (6–10 circuits, 30A or 50A to match the generator outlet): Installed by a qualified professional[Amazon]
- Generator interlock kit (listed for YOUR panel make/model — check before buying): Installed by a qualified professional[Amazon]
- 50A power inlet box + 6 AWG generator cord (or 30A L14-30 set, to match the generator outlet): Size the inlet and cord to the generator outlet[Amazon]
- Clamp meter with inrush function: Measure real starting currents at the panel[Amazon]
- Battery-operated carbon monoxide alarms (one per floor, near sleeping areas): Fit near sleeping areas[Amazon]
- Load-management module (e.g. Generac Smart Management Module class — dealer item; check compatibility with your standby unit): Dealer item — check compatibility first[Amazon]
Load-shedding rules — what to shed, in what order
Stagger motor starts: never start the well pump and the AC in the same moment — start the biggest motor first with other loads off. The AC starts with other heavy loads off (dryer, water heater and dishwasher paused). Switch the water heater to propane where possible (drops 1,400W in an RV, 4,500W for a tank heater — it leaves the load list entirely). A load manager or Generac Smart Management Module does this automatically on standby systems: it briefly pauses a lower-priority load when the generator nears overload.
| Shed first (biggest, least urgent) | Shed next | Shed last (protect these) |
|---|---|---|
| Electric dryer (6,000W), electric water heater (4,500W), EV charger (no watts printed — shed by category), electric range (all burners + oven) | Dishwasher (2,400W), microwave (1,500W), space heater (1,500W), second AC | Fridge + freezer, furnace fan, sump pump, well pump (if it is the water supply), lights, router, CPAP |
Frequently Asked Questions — Whole-House Generator Sizing
What size generator do I need for my whole house?
There is no one number — build the three lists in the Steps below. A critical-circuits list (fridge, freezer, furnace, sump, lights, TV, laptop, router, CPAP) is 3,222W running and 4,322W at the sump’s start — a 5000W-class portable covers it. Add a well pump, microwave and dishwasher and it is 9,122W / 11,122W peak — a 12000W-class portable or a 14 kW standby. Add a dryer, water heater and 3-ton central AC and it is 23,122W running — no portable covers it.
Should I get a transfer switch or an interlock kit?
A manual transfer switch powers 6–10 pre-selected circuits and makes overloading harder (about $400–$1,300 installed, 2026 guides). An interlock kit reaches any circuit in the panel but leaves load management to you (about $400–$850 installed). Both stop backfeeding; both need an electrician and, in most places, a permit. Pick the transfer switch if other people in the house will run things; pick the interlock if your panel has a listed kit and you will manage the load by hand.
What is a power inlet box — is it enough on its own?
No. The inlet box is just the weatherproof socket on the outside wall where the generator cord plugs in. It must be wired to a transfer switch or an interlocked breaker — never to a plain breaker, and never as the only safety device. A plain backfed breaker without an interlock can kill line workers.
How do I keep the generator from overloading when loads cycle on?
Shed in order: dryer and water heater first, then dishwasher and microwave, and start the biggest motor first with other heavy loads paused. A standby system does this automatically with a load manager, which briefly pauses a lower-priority load (e.g. the water heater) when the AC starts.
Can I size my generator from my house’s square footage?
No — size to loads, not square footage. Generac’s bands (a ~1,550 sq ft home at 10–18 kW; a ~2,000 sq ft home at 18–22 kW) are context only. Two houses the same size can need very different generators depending on whether they have a well pump, electric dryer, electric water heater and central AC. Build the load list.