20A DC-to-DC Charger Wire & Fuse Size Calculator
Designed for Renogy 12V 20A DC-DC, Victron Orion-Tr Smart 12/12-18A, Redarc BCDC1220. Important engineering note: a 20A output DC-DC charger can pull up to 25 Amps on the input cable from your starter battery when alternator voltage sags!
20A DC-to-DC Charger Cable Gauge Chart (Starter Battery to House Bank)
Calculated with `V_drop = (2 × L_ft × I × R_1000ft) / 1000` for pure copper wire keeping voltage drop ≤3% so smart-alternator voltage sensing never drops out:
| Chassis Cable Length | Recommended AWG Wire | Metric Equivalent | Voltage Drop | Starter & House Fuse Size |
|---|---|---|---|---|
| 5 ft (1.5 m) | 10 AWG | 5.26 mm² | 0.25V / 2.12% | 35A MIDI / MEGA / ANL |
| 10 ft (3.0 m) | 8 AWG | 8.36 mm² | 0.32V / 2.67% | 35A MIDI / MEGA / ANL |
| 15 ft (4.6 m) | 6 AWG | 13.3 mm² | 0.3V / 2.52% | 35A MIDI / MEGA / ANL |
| 20 ft (6.1 m) | 4 AWG | 21.2 mm² | 0.25V / 2.11% | 35A MIDI / MEGA / ANL |
| 25 ft (7.6 m) | 4 AWG | 21.2 mm² | 0.32V / 2.64% | 35A MIDI / MEGA / ANL |
| 30 ft (9.1 m) | 2 AWG | 33.6 mm² | 0.24V / 1.99% | 35A MIDI / MEGA / ANL |
Pre-Loaded: 20A DC-DC Charger (25A @ 15ft Campervan Chassis Run)
Real-time AWG sizing, thermal ampacity verification, SVG wiring diagram & shareable BOM generator
Tip: Type either Amps or Watts — both sync automatically.
Live Circuit Schematic & Conductor Scale Comparison
ABYC E-11 Rule: Fuse within 7" of Battery (+)Required Wiring Bill of Materials (BOM)
100% Code-Compliant Spec SheetAll Wire Gauges (18 AWG to 4/0 AWG) Performance Matrix for Current Load
Comparing voltage drop, power loss (heat), and maximum safe insulation ampacity| Wire Gauge | Metric (mm²) | Voltage Drop (V) | Voltage Drop (%) | Heat Loss (W) | Max Safe Amps | Engineering Status |
|---|---|---|---|---|---|---|
| 18 AWG | 0.82 mm² | 4.88V | 40.69% | 122.1W | 20A | Exceeds Ampacity |
| 16 AWG | 1.31 mm² | 3.07V | 25.56% | 76.7W | 25A | Exceeds Ampacity |
| 14 AWG | 2.08 mm² | 1.93V | 16.09% | 48.3W | 35A | Voltage Drop High |
| 12 AWG | 3.31 mm² | 1.21V | 10.12% | 30.4W | 45A | Voltage Drop High |
| 10 AWG | 5.26 mm² | 0.76V | 6.36% | 19.1W | 60A | Voltage Drop High |
| 8 AWG | 8.36 mm² | 0.48V | 4% | 12W | 80A | Voltage Drop High |
| 6 AWG | 13.3 mm² | 0.3V | 2.52% | 7.6W | 120A | ★ BEST MATCH |
| 4 AWG | 21.2 mm² | 0.19V | 1.58% | 4.7W | 160A | Safe (Lower Loss) |
| 2 AWG | 33.6 mm² | 0.12V | 0.99% | 3W | 210A | Safe (Lower Loss) |
| 1 AWG | 42.4 mm² | 0.09V | 0.79% | 2.4W | 210A | Safe (Lower Loss) |
| 1/0 AWG | 53.5 mm² | 0.07V | 0.63% | 1.9W | 235A | Safe (Lower Loss) |
| 2/0 AWG | 67.4 mm² | 0.06V | 0.5% | 1.5W | 330A | Safe (Lower Loss) |
| 3/0 AWG | 85 mm² | 0.05V | 0.39% | 1.2W | 350A | Safe (Lower Loss) |
| 4/0 AWG | 107.2 mm² | 0.04V | 0.31% | 0.9W | 445A | Safe (Lower Loss) |
How to Wire a 20A DC-to-DC Charger in 5 Steps
- Mount the DC-DC charger near the rear house battery (within 3–5 ft): Keep the 14.4V charging output wires short (6 AWG) so the charger reads accurate LiFePO4 terminal voltage.
- Install Fuse #1 within 7 inches of the starter battery (+): Fit a 35A MIDI or ANL fuse right at the vehicle starter battery post before routing the wire through the firewall or underbody.
- Route 6 AWG (up to 10 ft) or 4 AWG (12–20 ft) inside protective loom: Use rubber grommets through every metal bulkhead hole.
- Install Fuse #2 within 7 inches of the house battery busbar (+): Fit a second 30A MIDI/ANL fuse on the output line going to your house LiFePO4 positive busbar.
- Connect the D+ ignition trigger wire (if equipped with a smart alternator): Run an 18 AWG wire from an "Ignition ON / Run" fuse tap in your dash fuse box to the D+ terminal so the charger only runs when the engine is turning.
20A DC-DC Charger BOM & Shopping List
Alternator Health Tip: Check your vehicle's factory alternator rating before choosing a DC-DC charger. Never draw more than 30%–40% of a stock alternator's rated output continuously at idle.
Frequently Asked Questions — 20A DC-to-DC Charger Wiring
1. What size wire do I need for a 20A DC-to-DC charger?
A 20A 12V DC-DC charger (Renogy 12V 20A DC-DC, Victron Orion-Tr Smart 12/12-18A, Redarc BCDC1220) pulls up to 25A on the starter battery input cable. For a typical 15-foot campervan run, use 6 AWG pure copper cable to stay within a 3% voltage drop.
2. What size fuse is required for a 20A DC-to-DC battery charger?
Install a 35A MIDI, MEGA, or ANL fuse within 7 inches of the starter battery positive post, and a second 30A fuse within 7 inches of the house battery bank.
3. Why does a 20A DC-DC charger draw 25A on the input side?
When boosting 12.4V–13.2V alternator input up to 14.4V LiFePO4 absorption voltage at ~90% conversion efficiency, input current is 15%–25% higher than output current. Always size the starter-to-charger input wire for peak input amps.
4. What is the D+ ignition trigger wire on a DC-to-DC charger?
On vehicles with Euro 5/6 "smart" variable-voltage alternators, the D+ wire connects to an ignition-switched 12V fuse tap (16–18 AWG) so the DC-DC charger knows the engine is running even when the smart alternator drops voltage to 12.3V during highway coasting.
5. How close should the DC-DC charger be mounted to the house battery?
Mount the DC-DC charger as close as possible (within 2 to 5 feet) to your rear LiFePO4 house battery bank so the 14.4V charging output sees minimal voltage drop, and let the input cable cover the 15-foot distance from the front starter battery.