120A Anderson Plug (SB120) Wire Size & Fuse Calculator (4 AWG vs 2 AWG)
Connector Series: SB120 (120 Amp) • Max Contact Terminal Size: 2 AWG (33.6 mm²) • Typical Applications: High-output 60A–100A DC-DC chargers, heavy caravan battery links, and portable 1000W–1500W inverter disconnects.
Pre-Loaded: SB120 (120 Amp) (100A Continuous Load @ 15ft Run)
Real-time AWG sizing, thermal ampacity verification, SVG wiring diagram & shareable BOM generator
Volts
= 1,200 Watts
Amps
Watts
Tip: Type either Amps or Watts — both sync automatically.
Round-Trip Loop: 30 ft
Feet
Recommended Wire Size
1/0 AWG
53.5 mm² (8.25mm core) Drop Limited
Actual Voltage Drop
2.5%
(-0.3V)
At Load: 11.7V Heat Loss: 30W
Required Fuse & Lugs
125A Fuse
MRBF (Terminal Fuse Block) or MEGA / ANL Fuse Lug Stud: 3/8" (M10)
🚨 High Current / Long Run Alert: Single 4/0 AWG Exceeded!
Your load exceeds the safe ampacity or voltage drop limit of a single 4/0 AWG cable. You must either run two parallel pairs of 2/0 or 4/0 AWG cables (fused individually at the busbar) OR upgrade your system voltage to 24V / 48V to cut current in half.
Live Circuit Schematic & Conductor Scale Comparison
ABYC E-11 Rule: Fuse within 7" of Battery (+)Required Wiring Bill of Materials (BOM)
100% Code-Compliant Spec Sheet 1. Positive & Negative Battery Cable 1/0 AWG Pure Copper (15 ft Red + 15 ft Black)
2. Overcurrent Protection (Within 7" of Battery) 125A MRBF (Terminal Fuse Block) or MEGA / ANL Fuse
3. Crimp Ring Terminal Lugs (4x Required) 4x 1/0 AWG Heavy-Duty Lugs (3/8" (M10) Stud)
4. Adhesive-Lined Heat Shrink Tubing (3:1 Ratio) 1/2" or 3/4" Marine Dual-Wall Red & Black
All Wire Gauges (18 AWG to 4/0 AWG) Performance Matrix for Current Load
Comparing voltage drop, power loss (heat), and maximum safe insulation ampacity| Wire Gauge | Metric (mm²) | Voltage Drop (V) | Voltage Drop (%) | Heat Loss (W) | Max Safe Amps | Engineering Status |
|---|---|---|---|---|---|---|
| 18 AWG | 0.82 mm² | 19.53V | 162.75% | 1953W | 20A | Exceeds Ampacity |
| 16 AWG | 1.31 mm² | 12.27V | 102.25% | 1227W | 25A | Exceeds Ampacity |
| 14 AWG | 2.08 mm² | 7.72V | 64.38% | 772.5W | 35A | Exceeds Ampacity |
| 12 AWG | 3.31 mm² | 4.86V | 40.48% | 485.7W | 45A | Exceeds Ampacity |
| 10 AWG | 5.26 mm² | 3.05V | 25.45% | 305.4W | 60A | Exceeds Ampacity |
| 8 AWG | 8.36 mm² | 1.92V | 16% | 192W | 80A | Exceeds Ampacity |
| 6 AWG | 13.3 mm² | 1.21V | 10.08% | 120.9W | 120A | Exceeds Ampacity |
| 4 AWG | 21.2 mm² | 0.76V | 6.32% | 75.9W | 160A | Voltage Drop High |
| 2 AWG | 33.6 mm² | 0.48V | 3.98% | 47.7W | 210A | Voltage Drop High |
| 1 AWG | 42.4 mm² | 0.38V | 3.15% | 37.8W | 210A | Voltage Drop High |
| 1/0 AWG | 53.5 mm² | 0.3V | 2.5% | 30W | 235A | ★ BEST MATCH |
| 2/0 AWG | 67.4 mm² | 0.24V | 1.99% | 23.9W | 330A | Safe (Lower Loss) |
| 3/0 AWG | 85 mm² | 0.19V | 1.58% | 18.9W | 350A | Safe (Lower Loss) |
| 4/0 AWG | 107.2 mm² | 0.15V | 1.25% | 15W | 445A | Safe (Lower Loss) |
Advertisement • CLS-Protected Slot (anderson-120a-anderson-plug-wire-size)
Google AdSense / Header Bidding Unit Ready (Zero Layout Shift Container)
SB120 (120 Amp) Cable Gauge & Voltage Drop Chart (5ft to 30ft)
Note on terminal contacts: The standard SB120 (120 Amp) housing physically accepts up to 2 AWG (33.6 mm²) wire barrels. If your long chassis run requires a thicker gauge than 2 AWG (33.6 mm²) to prevent voltage drop, use a reducer pin or terminate at a heavy-duty busbar near the plug:
| One-Way Cable Run | Recommended AWG Wire | Metric Size (mm²) | Voltage Drop @ 100A | Recommended Fuse / Breaker |
|---|---|---|---|---|
| 5 ft One-Way | 4 AWG | 21.2 mm² | 2.11% (-0.25V) | 125A MIDI / ANL |
| 10 ft One-Way | 2 AWG | 33.6 mm² | 2.65% (-0.32V) | 125A MIDI / ANL |
| 15 ft One-Way | 1/0 AWG | 53.5 mm² | 2.5% (-0.3V) | 125A MIDI / ANL |
| 20 ft One-Way | 2/0 AWG | 67.4 mm² | 2.65% (-0.32V) | 125A MIDI / ANL |
| 25 ft One-Way | 3/0 AWG | 85 mm² | 2.63% (-0.32V) | 125A MIDI / ANL |
| 30 ft One-Way | 4/0 AWG | 107.2 mm² | 2.5% (-0.3V) | 125A MIDI / ANL |